The sensitivity of approved Ninhydrin and Biuret tests in the assessment of protein contamination on surgical steel as an aid to prevent iatrogenic prion transmission.

Lipscomb, I. P., Pinchin, H. E., Collin, R., Harris, K. and Keevil, C. W. (2006) The sensitivity of approved Ninhydrin and Biuret tests in the assessment of protein contamination on surgical steel as an aid to prevent iatrogenic prion transmission. The Journal of hospital infection, 64 (3). pp. 288-92. ISSN 0195-6701

Full text not available from this repository.

Abstract

Regulations recommend the routine application of biochemical tests, such as the Ninhydrin or Biuret tests, to confirm the efficacy of hospital sterile service department (SSD) washer-disinfector cycles in removing proteinaceous material, particularly with respect to prions. The effectiveness of these methods relies on both the effective sampling of the instruments and the sensitivity of the tests employed. Two commercially available contamination assessment tests were evaluated for their sensitivity to ME7 brain homogenate on surgical-grade stainless steel surfaces. Controls were visualized by the application of episcopic differential interference contrast/Epi-fluorecence microscopy (EDIC/EF) combined with the sensitive fluorescent reagent, SYPRO Ruby, which has been shown previously to rapidly visualize and assess low levels of contamination on medical devices. The Ninhydrin test displayed a minimum level of detection observed by 75% of volunteers (MLD(75)) of 9.25 microg [95% confidence interval (95% CI) 8.6-10.0 microg]. The Biuret test provided better sensitivity, with a MLD(75) of 6.7 microg (95% CI 5.4-8.2 microg). However, much lower concentrations of proteinaceous soiling (pg) were visualized using the EDIC/EF microscopy method. From these findings, it is clear that these approved colorimetric tests of cleaning are relatively insensitive. This investigation demonstrates how large amounts (up to 6.5 microg) of proteinaceous brain contamination could remain undetected and the instruments deemed clean using such methods. The application of more sensitive cleanliness evaluation methods should be applied to reduce the risk of iatrogenic transmission of prion disease in 'high-risk' instruments such as neurosurgical devices.

Publication Type: Articles
Subjects: Q Science > QR Microbiology
R Medicine > R Medicine (General)
Divisions: Academic Areas > Institute of Education, Social and Life Sciences > Education and Teaching
Depositing User: Ian Lipscomb
Date Deposited: 05 Oct 2016 14:45
Last Modified: 05 Oct 2016 14:45
URI: https://eprints.chi.ac.uk/id/eprint/2024

Actions (login required)

View Item
View Item
▲ Top

Our address

I’m looking for